Arterial puncture, platelet donation

Status: 
Ready to upload
Record number: 
1520
Adverse Occurrence type: 
MPHO Type: 
Estimated frequency: 
0.002%
Time to detection: 
immediate
Alerting signals, symptoms, evidence of occurrence: 
None provided. Usual signs and symptoms (ISBT definitions) include: lighter red colour than usual; the needle and tubing may appear to pulsate; the blood bag fills very quickly. There may be weak pain located to the elbow region.
Demonstration of imputability or root cause: 
Occurred during donation.
Imputability grade: 
3 Definite/Certain/Proven
Groups audience: 
Suggest new keywords: 
Arterial puncture, apheresis platelet
Reference attachment: 
Suggest references: 
Eder, A.F, Dy, B.A., Kennedy, J.M., Notari,IV, E.P., Strupp, A., Wissel, M.E., Reddy, R., Gibble, J., Haimowitz, M.D., Newman, B.H. Chambers, L.A. Hillyer, C.D. and Benjamin, R.J. (2008). The American Red Cross donor hemovigilance program: complications of blood donation reported in 2006. Transfusion 48(9): 1809-19.
Expert comments for publication: 
This was a review of all adverse donor reactions occurring within a one year period in the American Red Cross. The denominator was the number of satisfactory (complete) and incomplete donations. Collections included 6,014,472 whole blood (WB), 49,594 apheresis platelets and 228,183 combinations of automated red cell collections. Overall rates of adverse events were WB: 348/10,000 collections; apheresis platelets: 577/10,000 collections and automated red cells: 538/10,000 collections. Major reactions as defined by outside medical care were for WB: 3.2/10,000; automated red cells: 2.9/10,000; this data was not provided for apheresis platelet collections. No latency period was provided but is assumed to be at the time of donation or shortly after. No alerting signals were provided in the paper but were consistent with the ISBT definitions.